Launch the Eagle
Browser on a PC that has the Ingenico ISC250 attached.
Click the "Utilities"
link on the left hand side of the browser bar.
Select "Device
Configuration" from the menu that displays.
In Device Configuration,
highlight the device "Credit / Debit Pad."
Press <Enter>.
The Credit/Debit Pad window displays.
Make note of
the port number that displays on the screen as it will be
needed to complete the upgrade.
If custom logos
are used, select <Logos>. Otherwise continue to step
8.
Select <Device>.
The "Select Device" window displays
Select "Ingenico
isc250, RBA 3.00". Select <OK> to continue. Select
<Port>. Locate and select the COM port value noted in
step 6. Select <OK> to continue.
Select <LOGOS>
and enter the Idle Screen file values noted in step 7. Check
the "Enable custom logos" check box.
Select <OK>
to continue. The "PinPad Update" window displays
indicating the download progress of the logo files. This step
takes approximately 1 minute to complete. At the "Download
Finished" dialog, select <OK>.
Select Credit/Debit
Pad and press <Enter>. The Credit/Debit Pad window displays.
Select <Download>.
The "Download Credit/Debit Pad" window displays.
Select <Yes> to initiate the upgrade to RBA 3.00. A
new window will open Press <Enter> to begin the upgrade.
The counter
at the bottom of the screen indicates the progress which will
take approximately 1 hour to complete. When complete, the
ISC250 will rebood and display the "Download Finished"
window.
Select <OK>
and close Device Configuration. The ISC250 has been successfully
upgraded to RBA 3.00 and is ready for use.
Repeat steps
1-15 above on each PC with an Ingenico ISC250 Signature Capture
or Debit Pad.
All
ISC 250's must be upgraded to RBA 3.00 before moving to RBA level
15.05 or higher. The update from RBA 3.00 to RBA 15.05 takes approximately
15 minutes to complete and must be performed on each ISC 250 unit.
Launch the Eagle
Browser on a PC that has the Ingenico ISC250 attached.
Click the "Utilities"
link on the left hand side of the browser bar.
Select "Device
Configuration" from the menu that displays.
In Device Configuration,
highlight the device "Credit / Debit Pad."
Press <Enter>.
The Credit/Debit Pad window displays.
Make note of
the port number that displays on the screen as it will be
needed to complete the upgrade (not necessary if you are on
Release 25.1 or higher).
If custom logos
are used, select <Logos>. Otherwise continue to step
8 (not necessary if you are on Release 25.1 or higher).
Select <Device>.
The "Select Device" window displays
Select "Ingenico
isc250, RBA 15.05". (NOTE
for retailers on Release 26, we recommend you update to RBA
17.01, but the
pin pad must be on RBA 15.05 in order to upgrade to RBA 17.01.
The pin pad cannot be upgraded from RBA level pre 15 to RBA
17.01) Select
<OK> to continue. Select <Port>. Locate and select
the COM port value noted in step 6. Select <OK> to continue.
Select <LOGOS>
and enter the Idle Screen file values noted in step 7. Check
the "Enable custom logos" check box (not necessary
if you are on Release 25.1 or higher).
Select <OK>
to continue. The "PinPad Update" window displays
indicating the download progress of the logo files. This step
takes approximately 1 minute to complete. At the "Download
Finished" dialog, select <OK>.
Select Credit/Debit
Pad and press <Enter>. The Credit/Debit Pad window displays.
Select <Download>.
The "Download Credit/Debit Pad" window displays.
Select <Yest> to initiate the upgrade to RBA 15.05.
(NOTE for retailers
on Release 26, we recommend you update to RBA 17.01, but
the
pin pad must be on RBA 15.05 in order to upgrade to RBA 17.01.
The pin pad cannot be upgraded from RBA level pre 15 to RBA
17.01) A new
window will open Press <Enter> to begin the upgrade.
The counter
at the bottom of the screen indicates the progress which will
take approximately 15 minutes to complete. When complete,
the ISC250 will reboot and display the "Download Finished"
window.
Select <OK>
and close Device Configuration. The ISC250 has been successfully
upgraded to RBA 15.05 and is ready for use.(NOTE for
retailers on Release 26, we recommend you update to RBA 17.01,
but the pin
pad must be on RBA 15.05 in order to upgrade to RBA 17.01.
The pin pad cannot be upgraded from RBA level pre 15 to RBA
17.01)
Repeat steps
1-15 above on each PC with an Ingenico ISC250 Signature Capture
or Debit Pad.
Confirm the correct version
of RBA the pin pad is now running by waiting for the pin pad
to reboot after the upgrade. While it boots it will display
a screen for 5 seconds with the version of RBA. If
you were not able to see the RBA value prior to the screen
changing, you can manually reboot the pin pad by holding down
the CLEAR and MINUS buttons at the same time until the unit
begins the reboot process.
Documentation for downloading software
to the ISC250 is also available in Device
Configuration by selecting the Docs button
when configuring the specified device.